Skip to content
Fencer Intel
critical 9.3

CVE-2011-3321 json

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA P…

published 2011-09-15 15 y ago modified 2026-06-16 4 mo ago also EUVD-2011-3285

cvss
9.3
version 2.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
7.1%
EPSS 7.1% chance of exploitation in 30 days, percentile 94%
public exploits
0
none known

Summary

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308.

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-11-244-01 updated cvss 9.3

Siemens WinCC Flexible Runtime Heap Overflow

  • Siemens SIMATIC WinCC (TIA Portal) Runtime Advanced Siemens SIMATIC WinCC flexible Runtime
    affected: mitigation “Siemens, PCS7 Security Concept Recommendations and Notes: (http://support.automation.siemens.com/WW/view/en/22229786).”

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Exploit prediction

7.07% chance of exploitation in the next 30 days, higher than 94% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 2.0 9.3 AV:N/AC:M/Au:N/C:C/I:C/A:C

Classification

Weakness
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

References

Sources