Skip to content
Fencer Intel
high 7.8

CVE-2013-4775 in the critical feed json

NETGEAR ProSafe GS724Tv3 and GS716Tv2 with firmware 5.4.1.13 and earlier; GS748Tv4 with firmware 5.4.1.14; GS510TP with firmware 5.4.0.6; G…

published 12y ago modified 4mo ago also EUVD-2013-4621

cvss
7.8
version 2.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
15.0%
EPSS 15.0% chance of exploitation in 30 days, percentile 96%
public exploits
1
Exploit-DB

Summary

NETGEAR ProSafe GS724Tv3 and GS716Tv2 with firmware 5.4.1.13 and earlier; GS748Tv4 with firmware 5.4.1.14; GS510TP with firmware 5.4.0.6; GS752TPS, GS728TPS, GS728TS, and GS725TS with firmware 5.3.0.17; and GS752TXS and GS728TXS with firmware 6.1.0.12 allows remote attackers to read encrypted administrator credentials and other startup configurations via a direct request to filesystem/startup-config.

Is CVE-2013-4775 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Timeline

  1. First public exploit (EDB-27774)
  2. Published

Exploit prediction

14.96% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • EDB-27774 Netgear ProSafe - Information Disclosure webapps, 2013-08-22
  • encripto.no http://www.encripto.no/forskning/whitepapers/Netgear_prosafe_advisory_aug_2013.pdf referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
NVD 2.0 7.8 AV:N/AC:L/Au:N/C:C/I:N/A:N

Classification

Weakness
  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.