critical 9.3

CVE-2013-5021 json

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1…

published 13y ago modified 4mo ago also EUVD-2013-4863

cvss
9.3
version 2.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
2.1%
EPSS 2.1% chance of exploitation in 30 days, percentile 81%
public exploits
0
none known

Summary

Multiple absolute path traversal vulnerabilities in National Instruments cwui.ocx, as used in National Instruments LabWindows/CVI 2012 SP1 and earlier, National Instruments LabVIEW 2012 SP1 and earlier, the Data Analysis component in ABB DataManager 1 through 6.3.6, and other products allow remote attackers to create and execute arbitrary files via a full pathname in an argument to the ExportStyle method in the (1) CWNumEdit, (2) CWGraph, (3) CWBoolean, (4) CWSlide, or (5) CWKnob ActiveX control, in conjunction with file content in the (a) Caption or (b) FormatString property value.

Is CVE-2013-5021 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

2.07% chance of exploitation in the next 30 days, higher than 81% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 2.0 9.3 AV:N/AC:M/Au:N/C:C/I:C/A:C

Classification

Weakness
  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.