high 8.1

CVE-2017-12718 in the critical feed json

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.

published 8y ago modified 4mo ago also EUVD-2017-4257

cvss
8.1
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
12.8%
EPSS 12.8% chance of exploitation in 30 days, percentile 96%
public exploits
1
Exploit-DB

Summary

A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.

Is CVE-2017-12718 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-17-285-04A updated cvss 8.1

NXP Semiconductors MQX RTOS (Update A)

  • NXP Semiconductors MQX RTOS <= 4.1, <= 5.0
    affected: mitigation “NXP released MQX, Version 5.1 on January 31, 2018, which addresses both vulnerabilities.”

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

cisa ICSMA-17-250-02A updated cvss 3.7

Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Timeline

  1. First public exploit (EDB-43776)
  2. Published

Exploit prediction

12.79% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • EDB-43776 Smiths Medical Medfusion 4000 - 'DHCP' Denial of Service dos, 2018-01-18

CVSS scores

assigned by version score vector
NVD 3.0 8.1 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 6.8 AV:N/AC:M/Au:N/C:P/I:P/A:P

Affected products

  • n/a Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump

Classification

Weakness
  • CWE-120 Buffer Copy without Checking Size of Input
  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer