CVE-2017-12718 in the critical feed json
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6.
published 8y ago modified 4mo ago also EUVD-2017-4257
- cvss
- 8.1
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 12.8%
- EPSS 12.8% chance of exploitation in 30 days, percentile 96%
- public exploits
- 1
- Exploit-DB
Summary
A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation.
Is CVE-2017-12718 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-17-285-04A updated cvss 8.1
NXP Semiconductors MQX RTOS (Update A)
-
NXP Semiconductors MQX RTOS <= 4.1, <= 5.0affected: mitigation “NXP released MQX, Version 5.1 on January 31, 2018, which addresses both vulnerabilities.”
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
cisa ICSMA-17-250-02A updated cvss 3.7
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A)
-
Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump 1.1, 1.6, 1.5affected: vendor fix smiths-medical.custhelp.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Timeline
- First public exploit (EDB-43776)
- Published
Exploit prediction
12.79% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- EDB-43776 Smiths Medical Medfusion 4000 - 'DHCP' Denial of Service dos, 2018-01-18
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 8.1 | CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 6.8 | AV:N/AC:M/Au:N/C:P/I:P/A:P |
Affected products
- n/a Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump
Classification
References
-
exploit-db.com
/exploits/43776/
exploit, third-party-advisory, vdb-entry
-
ics-cert.us-cert.gov
/advisories/ICSMA-17-250-02A
third-party-advisory, us-government-resource
-
securityfocus.com
/bid/101252
vdb-entry, third-party-advisory
-
securityfocus.com
/bid/100665
vdb-entry, third-party-advisory