Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidential…

published 7y ago modified 4mo ago also EUVD-2018-3452

cvss
9.8
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.9%
EPSS 0.9% chance of exploitation in 30 days, percentile 60%
public exploits
0
none known

Summary

Moxa OnCell G3100-HSPA Series version 1.6 Build 17100315 and prior use a proprietary monitoring protocol that does not provide confidentiality, integrity, and authenticity security controls. All information is sent in plain text, and can be intercepted and modified. The protocol is vulnerable to remote unauthenticated disclosure of sensitive information, including the administrator's password. Under certain conditions, it's also possible to retrieve additional information, such as content of HTTP requests to the device, or the previously used password, due to memory leakages.

Is CVE-2018-11421 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

0.91% chance of exploitation in the next 30 days, higher than 60% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 3.0 9.8 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N

Classification

Weakness
  • CWE-319 Cleartext Transmission of Sensitive Information