CVE-2018-14558 kev in the critical feed json
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(631…
published 8y ago modified 4mo ago also EUVD-2018-6467
- cvss
- 9.8
- version 3.1, CNA
- cisa kev
- Exploited
- added 2021-11-03
- epss
- 8.5%
- EPSS 8.5% chance of exploitation in 30 days, percentile 95%
- public exploits
- 0
- none known
Summary
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input.
Patch / fix
cisa required action Apply updates per vendor instructions.
Is CVE-2018-14558 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerTimeline
- Published
- Added to CISA KEV
- CISA patch deadline
- CISA SSVC: exploitation active
Known exploited
- Added
- 5y ago
- Patch by
- 2022-05-03 (4y ago)
- Ransomware
- Not known
- Required action
- Apply updates per vendor instructions.
- Vendor, product
- Tenda, AC7, AC9, and AC10 Routers
- CISA name
- Tenda AC7, AC9, and AC10 Routers Command Injection Vulnerability
CISA SSVC
- Exploitation
- Active, exploited in the wild
- Automatable
- yes
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
8.51% chance of exploitation in the next 30 days, higher than 95% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- github.com https://github.com/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| CNA | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 10.0 | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-
github.com
/zsjevilhex/iot/blob/master/route/tenda/tenda-01/Tenda.md
broken-link, exploit, third-party-advisory
-
cisa.gov
/known-exploited-vulnerabilities-catalog?field_cve=CVE-2018-14558
government-resource, us-government-resource
Sources
- CVE List CVE-2018-14558
- NVD CVE-2018-14558
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.