CVE-2018-14781 json
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers Authentication Bypass by Capture-replay
published 8y ago modified 4mo ago also EUVD-2018-6665
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.7%
- EPSS 0.7% chance of exploitation in 30 days, percentile 53%
- public exploits
- 0
- none known
Summary
Medtronic MiniMed MMT
devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.
Is CVE-2018-14781 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSMA-18-219-02 updated cvss 5.3
Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)
-
Medtronic MMT-500 Remote Controller MMT-508 MiniMed pump Medtronic MMT-503 Remote Controller MMT-512 / MMT-712 Paradigm x12, MMT-523 / MMT-723 Paradigm Revel, MMT-523(K) / MMT-723(K) Paradigm, MMT-515 / MMT-715 Paradigm x15affected: vendor fix medtronic.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Exploit prediction
0.71% chance of exploitation in the next 30 days, higher than 53% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N |
| NVD | 3.0 | 5.3 | CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N |
| NVD | 2.0 | 2.9 | AV:A/AC:M/Au:N/C:N/I:P/A:N |
Affected products
- Medtronic MMT- 508 - MiniMed pump
- Medtronic MMT – 511 pump Paradigm
- Medtronic MMT – 512 / MMT – 712 Paradigm x12
- Medtronic MMT – 515 / MMT – 715 Paradigm x15
- Medtronic MMT – 522 / MMT – 722 Paradigm REAL-TIME
- Medtronic MMT – 522(K) / MMT – 722(K) Paradigm REAL-TIME
- Medtronic MMT – 523 / MMT – 723 Paradigm Revel
- Medtronic MMT – 523(K) / MMT – 723(K) Paradigm
- Medtronic MMT – 554 / MMT – 754 MiniMed Veo
- Medtronic MMT – 551 / MMT – 751 MiniMed 530G
Classification
References
- global.medtronic.com /xg-en/product-security/security-bulletins/minimed.html
-
ics-cert.us-cert.gov
/advisories/ICSMA-18-219-02
third-party-advisory, us-government-resource
-
securityfocus.com
/bid/105044
vdb-entry, third-party-advisory
Sources
- CVE List CVE-2018-14781
- NVD CVE-2018-14781
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.