Skip to content
Fencer Intel
medium 6.1

CVE-2018-4848 json

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

published 2018-06-14 8 y ago modified 2026-06-17 4 mo ago also EUVD-2018-16634

cvss
6.1
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
1.0%
EPSS 1.0% chance of exploitation in 30 days, percentile 62%
public exploits
0
none known

Summary

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Patch / fix

  • siemens scalance_x-200_irt_firmware 5.4.1
  • siemens scalance_x-200_firmware 5.2.3

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-18-163-02 updated cvss 5.8

Siemens SCALANCE X Switches (Update A)

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

Exploit prediction

0.99% chance of exploitation in the next 30 days, higher than 62% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 3.0 6.1 CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
NVD 2.0 4.3 AV:N/AC:M/Au:N/C:N/I:P/A:N

Affected products

  • Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)
  • Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
  • Siemens SCALANCE X-200RNA switch family
  • Siemens SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)

Classification

Weakness
  • CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page
  • CWE-79 Improper Neutralization of Input During Web Page Generation