Skip to content
Fencer Intel
high 8.1

CVE-2018-9075 json

Iomega and LenovoEMC NAS Web UI Vulnerabilities

published 2018-09-28 8 y ago modified 2026-06-17 4 mo ago also EUVD-2018-20678

cvss
8.1
version 3.0, NVD
cisa kev
Not listed
not in CISA's catalog
epss
4.1%
EPSS 4.1% chance of exploitation in 30 days, percentile 90%
public exploits
0
none known

Summary

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, when joining a PersonalCloud setup, an attacker can craft a command injection payload using backtick "``" characters in the client:password parameter. As a result, arbitrary commands may be executed as the root user. The attack requires a value __c and iomega parameter.

Exploit prediction

4.11% chance of exploitation in the next 30 days, higher than 90% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 3.0 8.1 CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
NVD 2.0 9.3 AV:N/AC:M/Au:N/C:C/I:C/A:C

Affected products

  • Lenovo Group LTD Iomega StorCenter
  • Lenovo Group LTD LenovoEMC
  • Lenovo Group LTD EZ Media and Backup Center

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.