CVE-2019-11014 json
The VStarCam vstc.vscam.client library and vstc.vscam shared object, as used in the Eye4 application (for Android, iOS, and Windows), do no…
published 7y ago modified 4mo ago also EUVD-2019-2725
- cvss
- 9.8
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 2.3%
- EPSS 2.3% chance of exploitation in 30 days, percentile 83%
- public exploits
- 0
- none known
Summary
The VStarCam vstc.vscam.client library and vstc.vscam shared object, as used in the Eye4 application (for Android, iOS, and Windows), do not prevent spoofing of the camera server. An attacker can create a fake camera server that listens for the client looking for a camera on the local network. When the camera responds to the client, it responds via the broadcast address, giving all information necessary to impersonate the camera. The attacker then floods the client with responses, causing the original camera to be denied service from the client, and thus causing the client to then communicate exclusively with the attacker's fake camera server. When connecting to the fake camera server, the client sends all details necessary to login to the camera (username and password).
Is CVE-2019-11014 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerExploit prediction
2.33% chance of exploitation in the next 30 days, higher than 83% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- blog.0x42424242.in http://blog.0x42424242.in/2019/03/vstarcam-investigational-security.html referenced PoC, tagged "exploit" by a source, unverified
- blog.0x42424242.in http://blog.0x42424242.in/2019/03/vstarcam-investigational-security_22.html referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 10.0 | AV:N/AC:L/Au:N/C:C/I:C/A:C |
Classification
- Weakness
-
- CWE-20 Improper Input Validation
References
-
blog.0x42424242.in
/2019/03/vstarcam-investigational-security.html
exploit, third-party-advisory
-
blog.0x42424242.in
/2019/03/vstarcam-investigational-security_22.html
exploit, third-party-advisory
Sources
- CVE List CVE-2019-11014
- NVD CVE-2019-11014
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.