CVE-2019-13940 json
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (…
published 6y ago modified 4mo ago also EUVD-2019-5207
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.7%
- EPSS 1.7% chance of exploitation in 30 days, percentile 77%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.1), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.X.17), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.X.17), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX 2010 (All versions), SIMATIC WinAC RTX F 2010 (All versions), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.X.17), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.X.17), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.X.17), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.X.17). Affected devices contain a vulnerability that could cause a denial of service condition of the web server by sending specially crafted HTTP requests to ports 80/tcp and 443/tcp.
Beyond the web service, no other functions or interfaces are affected by the denial of service condition.
Patch / fix
- siemens s7-1200_cpu_1211c_firmware 4.1
- siemens s7-1200_cpu_1212c_firmware 4.1
- siemens s7-1200_cpu_1214c_firmware 4.1
- siemens s7-1200_cpu_1215c_firmware 4.1
- siemens s7-1200_cpu_1217c_firmware 4.1
- siemens s7-1200_cpu_1212fc_firmware 4.1
- siemens s7-1200_cpu_1214fc_firmware 4.1
- siemens s7-1200_cpu_1215fc_firmware 4.1
- siemens siplus_s7-1200_firmware 4.1
- siemens siplus_cpu_1211c_firmware 4.1
- siemens siplus_cpu_1212c_firmware 4.1
- siemens siplus_cpu_1215c_firmware 4.1
Is CVE-2019-13940 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-042-05 updated cvss 5.3
Siemens SIMATIC S7 (Update B)
-
Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
show 17 moreshow fewer
-
Siemens SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)affected: mitigation, no fix planned
-
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) <V4.1affected: fixed in V4.1, mitigation support.industry.siemens.com
-
Siemens SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0) Siemens SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0)affected: mitigation, no fix planned
-
Siemens SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
-
Siemens SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) <V3.X.17affected: fixed in V3.X.17, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
1.70% chance of exploitation in the next 30 days, higher than 77% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C |
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L |
| NVD | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:N/I:N/A:P |
Affected products
- Siemens SIMATIC ET 200pro IM154-8 PN/DP CPU
- Siemens SIMATIC ET 200pro IM154-8F PN/DP CPU
- Siemens SIMATIC ET 200pro IM154-8FX PN/DP CPU
- Siemens SIMATIC ET 200S IM151-8 PN/DP CPU
- Siemens SIMATIC ET 200S IM151-8F PN/DP CPU
- Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants)
- Siemens SIMATIC S7-300 CPU 314C-2 PN/DP
- Siemens SIMATIC S7-300 CPU 315-2 PN/DP
- Siemens SIMATIC S7-300 CPU 315F-2 PN/DP
- Siemens SIMATIC S7-300 CPU 315T-3 PN/DP
- Siemens SIMATIC S7-300 CPU 317-2 PN/DP
- Siemens SIMATIC S7-300 CPU 317F-2 PN/DP
- Siemens SIMATIC S7-300 CPU 317T-3 PN/DP
- Siemens SIMATIC S7-300 CPU 317TF-3 PN/DP
- Siemens SIMATIC S7-300 CPU 319-3 PN/DP
- Siemens SIMATIC S7-300 CPU 319F-3 PN/DP
- Siemens SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)
- Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)
- Siemens SIMATIC WinAC RTX 2010
- Siemens SIMATIC WinAC RTX F 2010
- Siemens SIPLUS ET 200S IM151-8 PN/DP CPU
- Siemens SIPLUS ET 200S IM151-8F PN/DP CPU
- Siemens SIPLUS S7-300 CPU 314C-2 PN/DP
- Siemens SIPLUS S7-300 CPU 315-2 PN/DP
- Siemens SIPLUS S7-300 CPU 315F-2 PN/DP
- Siemens SIPLUS S7-300 CPU 317-2 PN/DP
- Siemens SIPLUS S7-300 CPU 317F-2 PN/DP
Classification
- Weakness
-
- CWE-400 Uncontrolled Resource Consumption
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-431678.pdf
vendor-advisory
Sources
- CVE List CVE-2019-13940
- NVD CVE-2019-13940