CVE-2019-19292 json
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0).
published 6y ago modified 4mo ago also EUVD-2019-8916
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 2.0%
- EPSS 2.0% chance of exploitation in 30 days, percentile 80%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection vulnerability in its XML-based communication protocol as provided by default on ports 5444/tcp and 5440/tcp. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.
Is CVE-2019-19292 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-070-01 updated cvss 8.8
ICSA-20-070-01_Siemens and PKE SiNVR/SiVMS Video Server (Update B)
-
Siemens Control Center Server (CCS) <V1.5.0affected: fixed in V1.5.0, mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-21-103-10 updated cvss 8.8
Siemens and PKE Control Center Server
-
Siemens Control Center Server (CCS) < V1.5.0affected: fixed in V1.5.0, mitigation “CVE-2019-18340 - Harden the CCS server to prevent local access by unauthorized users” sivms.cloud
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Exploit prediction
2.00% chance of exploitation in the next 30 days, higher than 80% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:U/RC:C |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
Affected products
- Siemens Control Center Server (CCS)
Classification
- Weakness
-
- CWE-89 Improper Neutralization of Special Elements used in an SQL Command
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-844761.pdf
mitigation, vendor-advisory
- cert-portal.siemens.com /productcert/pdf/ssa-761844.pdf
Sources
- CVE List CVE-2019-19292
- NVD CVE-2019-19292
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.