CVE-2019-19294 json
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0).
published 6y ago modified 4mo ago also EUVD-2019-8918
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.0%
- EPSS 1.0% chance of exploitation in 30 days, percentile 63%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The web interface of the Control Center Server (CCS) contains multiple stored Cross-site Scripting (XSS) vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content.
Is CVE-2019-19294 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-070-01 updated cvss 6.3
ICSA-20-070-01_Siemens and PKE SiNVR/SiVMS Video Server (Update B)
-
Siemens Control Center Server (CCS) <V1.5.0affected: fixed in V1.5.0, mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
cisa ICSA-21-103-10 updated cvss 6.3
Siemens and PKE Control Center Server
-
Siemens Control Center Server (CCS) < V1.5.0affected: fixed in V1.5.0, mitigation “CVE-2019-18340 - Harden the CCS server to prevent local access by unauthorized users” sivms.cloud
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Exploit prediction
1.01% chance of exploitation in the next 30 days, higher than 63% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:N/E:P/RL:U/RC:C |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:N/I:H/A:N |
| CNA | 3.1 | 5.4 | CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N |
| NVD | 2.0 | 3.5 | AV:N/AC:M/Au:S/C:N/I:P/A:N |
Affected products
- Siemens Control Center Server (CCS)
Classification
- Weakness
-
- CWE-79 Improper Neutralization of Input During Web Page Generation
References
Sources
- CVE List CVE-2019-19294
- NVD CVE-2019-19294
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.