Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext.
published 7y ago modified 4mo ago also EUVD-2019-13554
- cvss
- 9.8
- version 3.0, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.6%
- EPSS 1.6% chance of exploitation in 30 days, percentile 75%
- public exploits
- 0
- none known
Summary
Fuji Electric V-Server before 6.0.33.0 stores database credentials in project files as plaintext. An attacker that can gain access to the project file can recover the database credentials and gain access to the database server.
Patch / fix
- fujielectric v-server 6.0.33.0
Is CVE-2019-3947 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerExploit prediction
1.58% chance of exploitation in the next 30 days, higher than 75% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- tenable.com https://www.tenable.com/security/research/tra-2019-27 referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.0 | 9.8 | CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:P/I:N/A:N |
Affected products
- n/a Fuji Electric V-Server
Classification
- Weakness
-
- CWE-522 Insufficiently Protected Credentials