CVE-2019-5617 json
C4G BLIS Improper Access Control
published 7y ago modified 4mo ago also EUVD-2019-15192
- cvss
- 10.0
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.3%
- EPSS 1.3% chance of exploitation in 30 days, percentile 71%
- public exploits
- 0
- none known
Summary
Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.
Is CVE-2019-5617 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerExploit prediction
1.32% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- blog.rapid7.com https://blog.rapid7.com/2019/09/10/r7-2019-09-cve-2019-5617-cve-2019-5643-cve-2019-5644-c4g-blis-authentication-and-authorization-vulnerabilities-fixed/ referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 10.0 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 7.5 | AV:N/AC:L/Au:N/C:P/I:P/A:P |