Skip to content
Fencer Intel
medium 5.4

CVE-2019-6562 json

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is place…

published 7y ago modified 4mo ago also EUVD-2019-16121

cvss
5.4
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.7%
EPSS 0.7% chance of exploitation in 30 days, percentile 52%
public exploits
0
none known

Summary

In Philips Tasy EMR, Tasy EMR Versions 3.02.1744 and prior, the software incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

Is CVE-2019-6562 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSMA-19-120-01 updated cvss 4.1

Philips Tasy EMR (Update A)

  • Philips Tasy EMR <= 3.01.1744 Philips Tasy WebPortal <= 3.02.1757
    affected: vendor fix fda.gov

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

Exploit prediction

0.67% chance of exploitation in the next 30 days, higher than 52% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 3.1 5.4 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
NVD 2.0 3.5 AV:N/AC:M/Au:S/C:N/I:P/A:N

Affected products

  • Philips Philips Tasy EMR

Classification

Weakness
  • CWE-79 Improper Neutralization of Input During Web Page Generation

References