CVE-2019-6585 json
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SC…
published 6y ago modified 4mo ago also EUVD-2019-16144
- cvss
- 6.1
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.7%
- EPSS 0.7% chance of exploitation in 30 days, percentile 54%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed.
Patch / fix
- siemens scalance_s602_firmware 4.1
- siemens scalance_s612_firmware 4.1
- siemens scalance_s623_firmware 4.1
- siemens scalance_s627-2m_firmware 4.1
Is CVE-2019-6585 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-042-10 updated cvss 4.7
Siemens SCALANCE S-600 (Update B)
-
Siemens SCALANCE S602 >=V3.0_and_<V4.1 Siemens SCALANCE S612 >=V3.0_and_<V4.1 Siemens SCALANCE S623 >=V3.0_and_<V4.1 Siemens SCALANCE S627-2M >=V3.0_and_<V4.1affected: fixed in V4.1, mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
0.74% chance of exploitation in the next 30 days, higher than 54% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 6.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N |
| NVD | 2.0 | 4.3 | AV:N/AC:M/Au:N/C:N/I:P/A:N |
Affected products
- Siemens SCALANCE S602
- Siemens SCALANCE S612
- Siemens SCALANCE S623
- Siemens SCALANCE S627-2M
Classification
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-591405.pdf
vendor-advisory
-
us-cert.gov
/ics/advisories/icsa-20-042-10
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2019-6585
- NVD CVE-2019-6585
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.