Skip to content
Fencer Intel
high 7.5

CVE-2020-10291 json

RVD#3336: System information disclosure without authentication on KUKA simulators

published 6y ago modified 4mo ago also EUVD-2020-2746

cvss
7.5
version 3.0, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.4%
EPSS 1.4% chance of exploitation in 30 days, percentile 73%
public exploits
0
none known

Summary

Visual Components (owned by KUKA) is a robotic simulator that allows simulating factories and robots in order toimprove planning and decision-making processes. Visual Components software requires a special license which can beobtained from a network license server. The network license server binds to all interfaces (0.0.0.0) and listensfor packets over UDP port 5093. No authentication/authorization is required in order to communicate with theserver. The protocol being used is a property protocol by RMS Sentinel which provides the licensing infrastructurefor the network license server. RMS Sentinel license manager service exposes UDP port 5093 which provides sensitivesystem information that could be leveraged for further exploitation without any kind of authentication. Thisinformation includes detailed hardware and OS characteristics.After a decryption process, a textual protocol is found which contains a simple header with the requested command,application-identifier, and some arguments. The protocol leaks information regarding the receiving serverinformation, license information and managing licenses, among others.Through this flaw, attackers can retreive information about a KUKA simulation system, particularly, the version ofthe licensing server, which is connected to the simulator, and which will allow them to launch local simulationswith similar characteristics, further understanding the dynamics of motion virtualization and opening doors toother attacks (see RVDP#711 and RVDP#712 for subsequent vulnerabilities that compromise integrity andavailability).Beyond compromising simulations, Visual Components provides capabilities to interface with industrial machinery.Particularly, their PLC Connectivity feature 'makes it easy' to connect simulations with control systems usingeither the industry standard OPC UA or other supported vendor specific interfaces. This fills the gap of jumpingfrom simulation to real and enables attackers to pivot from the Visual Components simulator to robots or otherIndustrial Control System (ICS) devices, such as PLCs.

Is CVE-2020-10291 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

1.45% chance of exploitation in the next 30 days, higher than 73% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.0 7.5 CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
NVD 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
NVD 2.0 5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N

Affected products

  • KUKA Roboter GmbH Visual Components Network License Server 2.0.8

Classification

Weakness
  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.