CVE-2020-12005 json
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, Con…
published 6y ago modified 4mo ago also EUVD-2020-4321
- cvss
- 7.5
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.8%
- EPSS 1.8% chance of exploitation in 30 days, percentile 79%
- public exploits
- 0
- none known
Summary
FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.
Is CVE-2020-12005 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-20-163-02 updated cvss 7.5
Rockwell Automation FactoryTalk Linx Software (Update A)
-
Rockwell Automation Connected Components Workbench <= 12 Rockwell Automation ControlFLASH >= 14 Rockwell Automation ControlFLASH Plus >= 1 Rockwell Automation FactoryTalk Asset Centre >= 9 Rockwell Automation FactoryTalk Linx 6.00, 6.10, 6.11 Rockwell Automation FactoryTalk Linx CommDTM >= 1affected: vendor fix, mitigation “Patch Roll-up for CPR9 SRx (Login Required)” rockwellautomation.custhelp.com
+3 more productsfewer
Rockwell Automation RSLinx Classic <= 4.11.00 (Versions removed from the scope of this advisory) Rockwell Automation Studio 5000 Launcher >= 31 Rockwell Automation Studio 5000 Logix Designer software <= 32
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Exploit prediction
1.84% chance of exploitation in the next 30 days, higher than 79% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H |
| NVD | 2.0 | 7.8 | AV:N/AC:L/Au:N/C:N/I:N/A:C |
Affected products
- n/a FactoryTalk Linx, RSLinx Classic, Connected Components Workbench, ControlFLASH Plus, FactoryTalk Asset Centre, FactoryTalk Linx CommDTM, Studio 5000 Launcher, Studio 5000 Logix Designer software
Classification
- Weakness
-
- CWE-434 Unrestricted Upload of File with Dangerous Type
References
-
us-cert.gov
/ics/advisories/icsa-20-163-02
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2020-12005
- NVD CVE-2020-12005
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.