CVE-2020-15799 json
A vulnerability has been identified in SCALANCE X-200 switch family (incl.
published 5y ago modified 4mo ago also EUVD-2020-7782
- cvss
- 6.5
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.1%
- EPSS 1.1% chance of exploitation in 30 days, percentile 65%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0). The vulnerability could allow an unauthenticated attacker to reboot the device over the network by using special urls from integrated web server of the affected products.
Patch / fix
- siemens scalance_x200-4pirt_firmware 5.5.0
- siemens scalance_x201-3pirt_firmware 5.5.0
- siemens scalance_x202-2irt_firmware 5.5.0
- siemens scalance_x202-2pirt_firmware 5.5.0
- siemens scalance_x202-2pirt_siplus_net_firmware 5.5.0
- siemens scalance_x204irt_firmware 5.5.0
- siemens scalance_xb205-3_firmware 5.2.5
- siemens scalance_xb205-3ld_firmware 5.2.5
- siemens scalance_xb208_firmware 5.2.5
- siemens scalance_xb213-3_firmware 5.2.5
- siemens scalance_xb213-3ld_firmware 5.2.5
- siemens scalance_xb216_firmware 5.2.5
- siemens scalance_xc206-2_firmware 5.2.5
- siemens scalance_xc206-2g_poe__firmware 5.2.5
- siemens scalance_xc206-2g_poe_eec_firmware 5.2.5
- siemens scalance_xc206-2sfp_firmware 5.2.5
- siemens scalance_xc206-2sfp_eec_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_(e/ip)_firmware 5.2.5
- siemens scalance_xc206-2sfp_g_eec_firmware 5.2.5
Is CVE-2020-15799 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-21-012-05 updated cvss 7.5
Siemens SCALANCE X Products (Update B)
-
Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants) <V5.2.5affected: fixed in V5.2.5, mitigation support.industry.siemens.com
-
Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) <V5.5.0affected: fixed in V5.5.0, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
1.09% chance of exploitation in the next 30 days, higher than 65% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H |
| NVD | 2.0 | 7.1 | AV:N/AC:M/Au:N/C:N/I:N/A:C |
Affected products
- Siemens SCALANCE X-200 switch family (incl. SIPLUS NET variants)
- Siemens SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)
Classification
- Weakness
-
- CWE-306 Missing Authentication for Critical Functionality
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-139628.pdf
vendor-advisory
Sources
- CVE List CVE-2020-15799
- NVD CVE-2020-15799
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.