high 7.5

CVE-2020-5953 json

A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that derefer…

published 4y ago modified 2mo ago also EUVD-2020-27107

cvss
7.5
version 3.1, NVD
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 21%
public exploits
0
none known

Summary

A vulnerability exists in System Management Interrupt (SWSMI) handler of InsydeH2O UEFI Firmware code located in SWSMI handler that dereferences gRT (EFI_RUNTIME_SERVICES) pointer to call a GetVariable service, which is located outside of SMRAM. This can result in code execution in SMM (escalating privilege from ring 0 to ring -2).

Patch / fix

  • Siemens SIMATIC Field PG M5 V22.01.10
  • Siemens SIMATIC Field PG M6 V26.01.13
  • Siemens SIMATIC IPC127E V27.01.09
  • Siemens SIMATIC IPC227G V28.01.04
  • Siemens SIMATIC IPC277G V28.01.04
  • Siemens SIMATIC IPC277G PRO V28.01.04
  • Siemens SIMATIC IPC327G V28.01.04
  • Siemens SIMATIC IPC377G V28.01.04
  • Siemens SIMATIC IPC427E V21.01.17
  • Siemens SIMATIC IPC477E V21.01.17
  • Siemens SIMATIC IPC477E PRO V21.01.17
  • Siemens SIMATIC IPC627E V25.02.12
  • Siemens SIMATIC IPC647E V25.02.12
  • Siemens SIMATIC IPC677E V25.02.12
  • Siemens SIMATIC IPC847E V25.02.12
  • Siemens SIMATIC ITP1000 V23.01.10
  • Siemens SIPLUS IPC427E V21.01.17

Is CVE-2020-5953 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

0.28% chance of exploitation in the next 30 days, higher than 21% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
NVD 3.1 7.5 CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H
NVD 2.0 6.9 AV:L/AC:M/Au:N/C:C/I:C/A:C

Affected products

  • Siemens SIMATIC Field PG M5
  • Siemens SIMATIC Field PG M6
  • Siemens SIMATIC IPC127E
  • Siemens SIMATIC IPC227G
  • Siemens SIMATIC IPC277G
  • Siemens SIMATIC IPC277G PRO
  • Siemens SIMATIC IPC327G
  • Siemens SIMATIC IPC377G
  • Siemens SIMATIC IPC427E
  • Siemens SIMATIC IPC477E
  • Siemens SIMATIC IPC477E PRO
  • Siemens SIMATIC IPC627E
  • Siemens SIMATIC IPC647E
  • Siemens SIMATIC IPC677E
  • Siemens SIMATIC IPC847E
  • Siemens SIMATIC ITP1000
  • Siemens SIPLUS IPC427E