In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X…
published 6y ago modified 4mo ago also EUVD-2020-28104
- cvss
- 8.6
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.4%
- EPSS 1.4% chance of exploitation in 30 days, percentile 71%
- public exploits
- 0
- none known
Summary
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
Is CVE-2020-6964 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSMA-20-023-01 updated cvss 10.0
GE CARESCAPE, ApexPro, and Clinical Information Center systems
-
General Electric (GE) ApexPro Telemetry Server <= 4.2 General Electric (GE) B450 2.X General Electric (GE) B650 1.X, 2.X General Electric (GE) B850 2.X, 1.X General Electric (GE) CARESCAPE Central Station (CSCS) 2.X, 1.X General Electric (GE) CARESCAPE Telemetry Server 4.3, <= 4.2affected: vendor fix gehealthcare.com
+1 more productsfewer
General Electric (GE) Clinical Information Center (CIC) 4.X, 5.X
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
Exploit prediction
1.36% chance of exploitation in the next 30 days, higher than 71% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 8.6 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N |
| NVD | 2.0 | 5.0 | AV:N/AC:L/Au:N/C:N/I:P/A:N |
Affected products
- n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors
Classification
- Weakness
-
- CWE-306 Missing Authentication for Critical Functionality
References
-
us-cert.gov
/ics/advisories/icsma-20-023-01
third-party-advisory, us-government-resource
-
www3.gehealthcare.com
/~/media/downloads/us/support/site-planning/site-readiness/gehc-gateway_project_implementation_guide_pdf.pdf
product