Skip to content
Fencer Intel
medium 6.5

CVE-2021-0257 json

Junos OS: MX Series, EX9200 Series: Trio-based MPCs memory leak in VPLS with integrated routing and bridging (IRB) interface

published 5y ago modified 4mo ago also EUVD-2021-2876

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 34%
public exploits
0
none known

Summary

On Juniper Networks MX Series and EX9200 Series platforms with Trio-based MPCs (Modular Port Concentrators) where Integrated Routing and Bridging (IRB) interfaces are configured and mapped to a VPLS instance or a Bridge-Domain, certain Layer 2 network events at Customer Edge (CE) devices may cause memory leaks in the MPC of Provider Edge (PE) devices which can cause an out of memory condition and MPC restart. When this issue occurs, there will be temporary traffic interruption until the MPC is restored. An administrator can use the following CLI command to monitor the status of memory usage level of the MPC: user@device> show system resource-monitor fpc FPC Resource Usage Summary Free Heap Mem Watermark : 20 % Free NH Mem Watermark : 20 % Free Filter Mem Watermark : 20 % * - Watermark reached Slot # % Heap Free RTT Average RTT 1 87 PFE # % ENCAP mem Free % NH mem Free % FW mem Free 0 NA 88 99 1 NA 89 99 When the issue is occurring, the value of “% NH mem Free” will go down until the MPC restarts. This issue affects MX Series and EX9200 Series with Trio-based PFEs (Packet Forwarding Engines), including MX-MPC1-3D, MX-MPC1E-3D, MX-MPC2-3D, MX-MPC2E-3D, MPC-3D-16XGE, and CHAS-MXxx Series MPCs. No other products or platforms are affected by this issue. This issue affects Juniper Networks Junos OS on MX Series, EX9200 Series: 17.3 versions prior to 17.3R3-S10; 17.4 versions prior to 17.4R3-S3; 18.2 versions prior to 18.2R3-S7; 18.3 versions prior to 18.3R3-S4; 18.4 versions prior to 18.4R3-S6; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R3-S1; 19.4 versions prior to 19.4R2-S2, 19.4R3; 20.2 versions prior to 20.2R1-S3, 20.2R2; 20.3 versions prior to 20.3R1-S1,, 20.3R2. This issue does not affect Juniper Networks Junos OS: 17.3 versions prior to 17.3R3-S8; 17.4 versions prior to 17.4R3-S2; 18.1; 18.2 versions prior to 18.2R3-S4; 18.3 versions prior to 18.3R3-S2; 18.4 versions prior to 18.4R3-S1; 19.1; 19.2 versions prior to 19.2R2; 19.3 versions prior to 19.3R3; 19.4 versions prior to 19.4R2.

Patch / fix

  • Juniper Networks Junos OS 17.3R3-S10, 17.4R3-S3, 18.2R3-S7, 18.3R3-S4, 18.4R3-S6, 19.2R3-S2, 19.3R3-S1, 19.4R2-S2, 19.4R3, 20.2R1-S3, 20.2R2, 20.3R1-S1,, 20.3R2

Is CVE-2021-0257 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Exploit prediction

0.40% chance of exploitation in the next 30 days, higher than 34% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 6.5 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
NVD 3.1 6.5 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
NVD 2.0 3.3 AV:A/AC:L/Au:N/C:N/I:N/A:P

Affected products

  • Juniper Networks Junos OS

Classification

Weakness
  • CWE-400 Uncontrolled Resource Consumption
  • CWE-401 Missing Release of Memory after Effective Lifetime

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.