CVE-2021-23842 json
Use of Hard-coded Cryptographic Key
published 4y ago modified 4mo ago also EUVD-2021-10768
- cvss
- 5.7
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.1%
- EPSS 0.1% chance of exploitation in 30 days, percentile 3%
- public exploits
- 0
- none known
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
Patch / fix
- Bosch AMS 4.0
- Bosch BIS 4.9.1
Is CVE-2021-23842 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerExploit prediction
0.14% chance of exploitation in the next 30 days, higher than 3% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.7 | CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N |
| NVD | 3.1 | 7.1 | CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N |
| NVD | 2.0 | 3.6 | AV:L/AC:L/Au:N/C:P/I:P/A:N |
Affected products
- Bosch AMS
- Bosch APE
- Bosch BIS
- Bosch AMC2
Classification
References
-
psirt.bosch.com
/security-advisories/BOSCH-SA-940448-BT.html
mitigation, vendor-advisory
Sources
- CVE List CVE-2021-23842
- NVD CVE-2021-23842
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.