CVE-2022-2336 json
Softing Secure Integration Server Improper Authentication
published 4y ago modified 4mo ago also EUVD-2022-34605
- cvss
- 9.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.1%
- EPSS 1.1% chance of exploitation in 30 days, percentile 65%
- public exploits
- 0
- none known
Summary
Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin` password. There is no warning or prompt to ask the user to change the default password, and to change the password, many steps are required.
Is CVE-2022-2336 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-22-228-04 updated cvss 9.8
Softing Secure Integration Server
-
Softing edgeAggregator 3.1 Softing edgeConnector 3.1 Softing OPC Suite 5.2 Softing OPC UA C++ Server SDK 6 Softing Secure Integration Server <= 1.22 Softing uaGate 1.74affected: mitigation “Softing Secure Integration Server: V1.30” industrial.softing.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
1.08% chance of exploitation in the next 30 days, higher than 65% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Softing Secure Integration Server
- Softing edgeConnector Siemens
- Softing edgeConnector 840D
- Softing edgeConnector Modbus
- Softing edgeAggregator
Classification
- Weakness
-
- CWE-287 Improper Authentication
References
-
industrial.softing.com
/fileadmin/psirt/downloads/syt-2022-6.html
mitigation, vendor-advisory
-
cisa.gov
/uscert/ics/advisories/icsa-22-228-04
third-party-advisory, us-government-resource
Sources
- CVE List CVE-2022-2336
- NVD CVE-2022-2336
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.