CVE-2022-29032 json
A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcen…
published 4y ago modified 4mo ago also EUVD-2022-33462
- cvss
- 7.8
- version 3.1, NVD
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.8%
- EPSS 0.8% chance of exploitation in 30 days, percentile 57%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in JT2Go (All versions < V13.3.0.3), Teamcenter Visualization V13.3 (All versions < V13.3.0.3), Teamcenter Visualization V14.0 (All versions < V14.0.0.1). The CGM_NIST_Loader.dll library contains a double free vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Patch / fix
- siemens jt2go 13.3.0.3
- siemens teamcenter_visualization 13.3.0.3, 14.0.0.1
Is CVE-2022-29032 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-22-132-09 updated cvss 7.8
Siemens JT2GO and Teamcenter Visualization
-
Siemens JT2Go <V13.3.0.3affected: fixed in V13.3.0.3, mitigation plm.automation.siemens.com
-
Siemens Teamcenter Visualization V13.3 <V13.3.0.3affected: fixed in V13.3.0.3, mitigation support.sw.siemens.com
-
Siemens Teamcenter Visualization V14.0 <V14.0.0.1affected: fixed in V14.0.0.1, mitigation support.sw.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
0.81% chance of exploitation in the next 30 days, higher than 57% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| NVD | 3.1 | 7.8 | CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H |
| NVD | 2.0 | 6.8 | AV:N/AC:M/Au:N/C:P/I:P/A:P |
Affected products
- Siemens JT2Go
- Siemens Teamcenter Visualization V13.3
- Siemens Teamcenter Visualization V14.0
Classification
- Weakness
-
- CWE-415 Double Free
References
-
cert-portal.siemens.com
/productcert/pdf/ssa-553086.pdf
patch, vendor-advisory
Sources
- CVE List CVE-2022-29032
- NVD CVE-2022-29032