CVE-2022-35868 json
A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions < V15.1 Update 8), T…
published 3y ago modified 4mo ago also EUVD-2022-38741
- cvss
- 7.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 8%
- public exploits
- 0
- none known
Summary
A vulnerability has been identified in TIA Multiuser Server V14 (All versions), TIA Multiuser Server V15 (All versions < V15.1 Update 8), TIA Project-Server (All versions < V1.1), TIA Project-Server V16 (All versions), TIA Project-Server V17 (All versions < V17 Update 6). Affected applications contain an untrusted search path vulnerability that could allow an attacker to escalate privileges, when tricking a legitimate user to start the service from an attacker controlled path.
Is CVE-2022-35868 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-23-047-07 updated cvss 6.7
Siemens TIA Project-Server formerly known as TIA Multiuser Server
-
Siemens TIA Multiuser Server V14affected: mitigation, no fix planned
-
Siemens TIA Multiuser Server V15 <V15.1_Update_8affected: fixed in V15.1, mitigation support.industry.siemens.com
-
Siemens TIA Project-Server <V1.1affected: fixed in V1.1, mitigation support.industry.siemens.com
-
Siemens TIA Project-Server V16affected: mitigation, no fix planned
-
Siemens TIA Project-Server V17 <V17_Update_6affected: fixed in V17, mitigation support.industry.siemens.com
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
Exploit prediction
0.19% chance of exploitation in the next 30 days, higher than 8% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.7 | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C |
| CNA | 3.1 | 6.7 | CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H |
| CNA | 3.1 | 7.3 | CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H |
Affected products
- Siemens TIA Multiuser Server V14
- Siemens TIA Multiuser Server V15
- Siemens TIA Project-Server
- Siemens TIA Project-Server V16
- Siemens TIA Project-Server V17
Classification
- Weakness
-
- CWE-426 Untrusted Search Path
References
Sources
- CVE List CVE-2022-35868
- NVD CVE-2022-35868
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.