CVE-2024-20275 json
Cisco Secure Firewall Management Center Software Backup Cluster Command Injection Vulnerability
published 2y ago modified 4mo ago also EUVD-2024-17990
- cvss
- 6.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 46%
- public exploits
- 0
- none known
Summary
A vulnerability in the cluster backup feature of Cisco Secure Firewall Management Center (FMC) Software, formerly Firepower Management Center Software, could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system.
This vulnerability is due to insufficient validation of user data that is supplied through the web-based management interface. An attacker could exploit this vulnerability by sending a crafted HTTP request to an affected device. A successful exploit could allow the attacker to execute arbitrary operating system commands on the affected device. To exploit this vulnerability, an attacker would need valid credentials for a user account with at least the role of Network Administrator. In addition, the attacker would need to persuade a legitimate user to initiate a cluster backup on the affected device.
Is CVE-2024-20275 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- 2y ago
Exploit prediction
0.55% chance of exploitation in the next 30 days, higher than 46% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 6.8 | CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:N |
Affected products
- Cisco Cisco Firepower Management Center
- cisco secure_firewall_management_center_software
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-
sec.cloudapps.cisco.com
/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-cmd-inj-g8AOKnDP
vendor-advisory
-
sec.cloudapps.cisco.com
/security/center/viewErp.x?alertId=ERP-75300
vendor-advisory
-
sec.cloudapps.cisco.com
/security/center/content/CiscoSecurityAdvisory/cisco-sa-fmc-xss-M446vbEO