CVE-2024-23962 json
Alpine Halo9 Missing Authentication
published last yr. modified 4mo ago also EUVD-2024-21388
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.7%
- EPSS 0.7% chance of exploitation in 30 days, percentile 53%
- public exploits
- 0
- none known
Summary
This vulnerability allows remote attackers to disclose sensitive information on affected installations of Alpine Halo9 devices. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the DLT interface, which listens on TCP port 3490 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device.
Is CVE-2024-23962 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- last yr.
Exploit prediction
0.70% chance of exploitation in the next 30 days, higher than 53% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N |
Affected products
- Alpine Halo9
Classification
- Weakness
-
- CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
References
-
zerodayinitiative.com
/advisories/ZDI-24-847/
third-party-advisory
Sources
- CVE List CVE-2024-23962
- NVD CVE-2024-23962
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.