CVE-2024-23968 json
ChargePoint Home Flex SrvrToSmSetAutoChnlListMsg Stack-based Buffer Overflow
published last yr. modified 4mo ago also EUVD-2024-21394
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.5%
- EPSS 0.5% chance of exploitation in 30 days, percentile 42%
- public exploits
- 0
- none known
Summary
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the SrvrToSmSetAutoChnlListMsg function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root.
Is CVE-2024-23968 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
0.48% chance of exploitation in the next 30 days, higher than 42% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- ChargePoint Home Flex
Classification
- Weakness
-
- CWE-120 Buffer Copy without Checking Size of Input
References
-
zerodayinitiative.com
/advisories/ZDI-24-1050/
third-party-advisory
Sources
- CVE List CVE-2024-23968
- NVD CVE-2024-23968
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.