Skip to content
Fencer Intel
critical 10.0

CVE-2024-30207 json

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manag…

published 2y ago modified 4mo ago also EUVD-2024-28139

cvss
10.0
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.8%
EPSS 0.8% chance of exploitation in 30 days, percentile 58%
public exploits
0
none known

Summary

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The affected systems use symmetric cryptography with a hard-coded key to protect the communication between client and server. This could allow an unauthenticated remote attacker to compromise confidentiality and integrity of the communication and, subsequently, availability of the system. A successful exploit requires the attacker to gain knowledge of the hard-coded key and to be able to intercept the communication between client and server on the network.

Patch / fix

  • Siemens SIMATIC RTLS Locating Manager V3.0.1.1

Is CVE-2024-30207 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-24-137-07 updated cvss 10.0

Siemens SIMATIC RTLS Locating Manager

  • Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA00) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA10) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA20) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-0DA30) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA10) <V3.0.1.1 Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA20) <V3.0.1.1
    +1 more products
    Siemens SIMATIC RTLS Locating Manager (6GT2780-1EA30) <V3.0.1.1
    affected: fixed in V3.0.1.1, mitigation

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
2y ago

Exploit prediction

0.84% chance of exploitation in the next 30 days, higher than 58% of all scored CVEs (FIRST EPSS, 2026-11-11).

CVSS scores

assigned by version score vector
CNA 3.1 10.0 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA 4.0 10.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H
CNA 4.0 10.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CNA 3.1 10.0 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Affected products

  • Siemens SIMATIC RTLS Locating Manager
  • siemens simatic_rtls_locating_manager

Classification

Weakness
  • CWE-321 Use of Hard-coded Cryptographic Key

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.