Skip to content
Fencer Intel
medium 6.3

CVE-2024-4965 json

D-Link DAR-7000-40 resmanage.php os command injection

published 2y ago modified 4mo ago also EUVD-2024-44522

cvss
6.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
2.9%
EPSS 2.9% chance of exploitation in 30 days, percentile 86%
public exploits
0
none known

Summary

** UNSUPPORTED WHEN ASSIGNED ** A vulnerability was found in D-Link DAR-7000-40 V31R02B1413C and classified as critical. This issue affects some unknown processing of the file /useratte/resmanage.php. The manipulation of the argument load leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-264533 was assigned to this vulnerability. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: Vendor was contacted early and confirmed immediately that the product is end-of-life. It should be retired and replaced.

Is CVE-2024-4965 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
2y ago

Exploit prediction

2.85% chance of exploitation in the next 30 days, higher than 86% of all scored CVEs (FIRST EPSS, 2026-11-11).

Exploits and checks

  • github.com https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/%3CWHB%7Cj%5CIbSU0m4%3A_/D-LINK-DAR-7000_RCE_%20resmanage.php.pdf referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CNA 3.0 6.3 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 9.8 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • D-Link DAR-7000-40

Classification

Weakness
  • CWE-78 Improper Neutralization of Special Elements used in an OS Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.