Skip to content
Fencer Intel
high 7.4

CVE-2024-52330 json

ECOVACS lawnmowers and vacuums do not properly validate TLS certificates

published last yr. modified 4mo ago also EUVD-2024-46259

cvss
7.4
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 29%
public exploits
0
none known

Summary

ECOVACS lawnmowers and vacuums do not properly validate TLS certificates. An unauthenticated attacker can read or modify TLS traffic, possibly modifying firmware updates.

Patch / fix

  • ECOVACS DEEBOT X5 PRO PLUS 1.38.0
  • ECOVACS DEEBOT X5 PRO 1.70.0
  • ECOVACS DEEBOT X2S 1.49.0
  • ECOVACS DEEBOT X2 OMNI 1.76.6
  • ECOVACS DEEBOT X1 TURBO 2.4.41
  • ECOVACS DEEBOT X1 1.7.3
  • ECOVACS DEEBOT X1S PRO 2.5.31
  • ECOVACS DEEBOT X1e OMNI 2.4.42
  • ECOVACS DEEBOT T10 PLUS 1.7.5
  • ECOVACS DEEBOT T10 OMNI 1.9.0
  • ECOVACS DEEBOT X5 PRO ULTRA 1.17.0
  • ECOVACS Mate X 1.44.18
  • ECOVACS DEEBOT X2 PRO 1.76.6
  • ECOVACS DEEBOT X2 COMBO 1.81.10
  • ECOVACS DEEBOT X1 OMNI 2.4.41
  • ECOVACS DEEBOT X1 PRO OMNI 2.4.41
  • ECOVACS DEEBOT X1 PLUS 1.7.3
  • ECOVACS DEEBOT X1S PRO PLUS 1.23.0
  • ECOVACS DEEBOT T10 TURBO 1.10.0
  • ECOVACS DEEBOT T10 1.7.5

Is CVE-2024-52330 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa vex VA-25-022-01 updated cvss 7.4

ECOVACS lawnmower and vacuum vulnerabilities

  • ECOVACS DEEBOT T10 <1.7.5 ECOVACS DEEBOT T10 OMNI <1.9.0 ECOVACS DEEBOT T10 PLUS <1.7.5 ECOVACS DEEBOT T10 TURBO <1.10.0 ECOVACS DEEBOT X1 <1.7.3 ECOVACS DEEBOT X1 OMNI <2.4.41
    +14 more products
    ECOVACS DEEBOT X1 PLUS <1.7.3 ECOVACS DEEBOT X1 PRO OMNI <2.4.41 ECOVACS DEEBOT X1 TURBO <2.4.41 ECOVACS DEEBOT X1e OMNI <2.4.42 ECOVACS DEEBOT X1S PRO <2.5.31 ECOVACS DEEBOT X1S PRO PLUS <1.23.0 ECOVACS DEEBOT X2 OMNI <1.76.6 ECOVACS DEEBOT X2 COMBO <1.81.10 ECOVACS DEEBOT X2 PRO <1.76.6 ECOVACS DEEBOT X2S <1.49.0 ECOVACS DEEBOT X5 PRO <1.70.0 ECOVACS DEEBOT X5 PRO PLUS <1.38.0 ECOVACS DEEBOT X5 PRO ULTRA <1.17.0 ECOVACS Mate X <1.44.18
    affected: vendor fix ecovacs.com
  • ECOVACS DEEBOT T10 1.7.5 ECOVACS DEEBOT T10 OMNI 1.9.0 ECOVACS DEEBOT T10 PLUS 1.7.5 ECOVACS DEEBOT T10 TURBO 1.10.0 ECOVACS DEEBOT X1 1.7.3 ECOVACS DEEBOT X1 OMNI 2.4.41
    +14 more products
    ECOVACS DEEBOT X1 PLUS 1.7.3 ECOVACS DEEBOT X1 PRO OMNI 2.4.41 ECOVACS DEEBOT X1 TURBO 2.4.41 ECOVACS DEEBOT X1e OMNI 2.4.42 ECOVACS DEEBOT X1S PRO 2.5.31 ECOVACS DEEBOT X1S PRO PLUS 1.23.0 ECOVACS DEEBOT X2 OMNI 1.76.6 ECOVACS DEEBOT X2 COMBO 1.81.10 ECOVACS DEEBOT X2 PRO 1.76.6 ECOVACS DEEBOT X2S 1.49.0 ECOVACS DEEBOT X5 PRO 1.70.0 ECOVACS DEEBOT X5 PRO PLUS 1.38.0 ECOVACS DEEBOT X5 PRO ULTRA 1.17.0 ECOVACS Mate X 1.44.18
    fixed: vendor fix ecovacs.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
total
Assessed
last yr.

Exploit prediction

0.35% chance of exploitation in the next 30 days, higher than 29% of all scored CVEs (FIRST EPSS, 2026-11-11).

Exploits and checks

  • dontvacuum.me https://dontvacuum.me/talks/HITCON2024/HITCON-CMT-2024_Ecovacs.pdf referenced PoC, tagged "exploit" by a source, unverified
  • dontvacuum.me https://dontvacuum.me/talks/37c3-2023/37c3-vacuuming-and-mowing.pdf referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 3.1 7.4 CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
CNA 4.0 9.5 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H
CNA 4.0 9.5 CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • ECOVACS DEEBOT X5 PRO PLUS
  • ECOVACS DEEBOT X5 PRO
  • ECOVACS DEEBOT X2S
  • ECOVACS DEEBOT X2 OMNI
  • ECOVACS DEEBOT X1 TURBO
  • ECOVACS DEEBOT X1
  • ECOVACS DEEBOT X1S PRO
  • ECOVACS DEEBOT X1e OMNI
  • ECOVACS DEEBOT T10 PLUS
  • ECOVACS DEEBOT T10 OMNI
  • ECOVACS DEEBOT X5 PRO ULTRA
  • ECOVACS Mate X
  • ECOVACS DEEBOT X2 PRO
  • ECOVACS DEEBOT X2 COMBO
  • ECOVACS DEEBOT X1 OMNI
  • ECOVACS DEEBOT X1 PRO OMNI
  • ECOVACS DEEBOT X1 PLUS
  • ECOVACS DEEBOT X1S PRO PLUS
  • ECOVACS DEEBOT T10 TURBO
  • ECOVACS DEEBOT T10

Classification

Weakness
  • CWE-295 Improper Certificate Validation

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.