CVE-2024-52508 json
Nextcloud Mail auto configurator can be tricked into sending account information to wrong servers
published last yr. modified 4mo ago also EUVD-2024-45922
- cvss
- 8.2
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.8%
- EPSS 0.8% chance of exploitation in 30 days, percentile 55%
- public exploits
- 0
- none known
Summary
Nextcloud Mail is the mail app for Nextcloud, a self-hosted productivity platform. When a user is trying to set up a mail account with an email address like user@example.tld that does not support auto configuration, and an attacker managed to register autoconfig.tld, the used email details would be send to the server of the attacker. It is recommended that the Nextcloud Mail app is upgraded to 1.14.6, 1.15.4, 2.2.11, 3.6.3, 3.7.7 or 4.0.0.
Patch / fix
- nextcloud nextcloud_mail 1.14.6, 2.2.11, 3.6.3, 3.7.7, 15.4.0
- github.com/nextcloud/mail@a84c70e commit
- github.com/nextcloud/mail#9964 pull request
Is CVE-2024-52508 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- total
- Assessed
- last yr.
Exploit prediction
0.75% chance of exploitation in the next 30 days, higher than 55% of all scored CVEs (FIRST EPSS, 2026-11-11).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 3.1 | 8.2 | CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:L |
| NVD | 3.1 | 8.1 | CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N |
Affected products
- nextcloud security-advisories
- nextcloud nextcloud_mail
Classification
- Weakness
-
- CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
References
Sources
- CVE List CVE-2024-52508
- NVD CVE-2024-52508
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.
CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.