CVE-2024-9004 json
D-Link DAR-7000 Backup_Server_commit.php os command injection
published 2y ago modified 4mo ago also EUVD-2024-49658
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 17.2%
- EPSS 17.2% chance of exploitation in 30 days, percentile 97%
- public exploits
- 0
- none known
Summary
A vulnerability classified as critical has been found in D-Link DAR-7000 up to 20240912. Affected is an unknown function of the file /view/DBManage/Backup_Server_commit.php. The manipulation of the argument host leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
Is CVE-2024-9004 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- 2y ago
Exploit prediction
17.25% chance of exploitation in the next 30 days, higher than 97% of all scored CVEs (FIRST EPSS, 2026-11-11).
Exploits and checks
- github.com https://github.com/mhtcshe/cve/blob/main/cve.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- D-Link DAR-7000
Classification
- Weakness
-
- CWE-78 Improper Neutralization of Special Elements used in an OS Command
References
-
github.com
/mhtcshe/cve/blob/main/cve.md
exploit, third-party-advisory
-
supportannouncement.us.dlink.com
/security/publication.aspx?name=SAP10354
related, vendor-advisory
-
vuldb.com
/?id.278154
vdb-entry, technical-description, permissions-required
-
vuldb.com
/?ctiid.278154
signature, permissions-required
-
vuldb.com
/?submit.407023
third-party-advisory
-
dlink.com
/
product
Sources
- CVE List CVE-2024-9004
- NVD CVE-2024-9004
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.