CVE-2024-9914 json
D-Link DIR-619L B1 formSetWizardSelectMode buffer overflow
published 2y ago modified 4mo ago also EUVD-2024-50206
- cvss
- 8.8
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 1.7%
- EPSS 1.7% chance of exploitation in 30 days, percentile 76%
- public exploits
- 0
- none known
Summary
A vulnerability classified as critical has been found in D-Link DIR-619L B1 2.06. Affected is the function formSetWizardSelectMode of the file /goform/formSetWizardSelectMode. The manipulation of the argument curTime leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Is CVE-2024-9914 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- total
- Assessed
- 2y ago
Exploit prediction
1.66% chance of exploitation in the next 30 days, higher than 76% of all scored CVEs (FIRST EPSS, 2026-11-11).
Exploits and checks
- github.com https://github.com/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetWizardSelectMode.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N |
| CNA | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 3.0 | 8.8 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
| CNA | 2.0 | 9.0 | AV:N/AC:L/Au:S/C:C/I:C/A:C |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 8.8 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H |
Affected products
- D-Link DIR-619L B1
- d-link dir-619l_b1
Classification
- Weakness
-
- CWE-120 Buffer Copy without Checking Size of Input
References
-
github.com
/abcdefg-png/IoT-vulnerable/blob/main/D-Link/DIR-619L/formSetWizardSelectMode.md
exploit, third-party-advisory
-
vuldb.com
/?id.280242
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.280242
signature, permissions-required, third-party-advisory, vdb-entry
-
vuldb.com
/?submit.418746
third-party-advisory, vdb-entry
-
dlink.com
/
product
Sources
- CVE List CVE-2024-9914
- NVD CVE-2024-9914
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.