CVE-2025-10541 json

Local Privilege Escalation via Insecure Update Mechanism in iMonitor EAM

published last yr. modified last mo. also EUVD-2025-31107

cvss
7.8
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.2%
EPSS 0.2% chance of exploitation in 30 days, percentile 12%
public exploits
0
none known

Summary

iMonitor EAM 9.6394 installs a system service (eamusbsrv64.exe) that runs with NT AUTHORITY\SYSTEM privileges. This service includes an insecure update mechanism that automatically loads files placed in the C:\sysupdate\ directory during startup. Because any local user can create and write to this directory, an attacker can place malicious DLLs or executables in it. Upon service restart, the files are moved to the application’s installation path and executed with SYSTEM privileges, leading to privilege escalation.

Is CVE-2025-10541 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
total
Assessed
last yr.

Exploit prediction

0.22% chance of exploitation in the next 30 days, higher than 12% of all scored CVEs (FIRST EPSS, 2026-11-11).

Exploits and checks

  • sec-consult.com https://sec-consult.com/vulnerability-lab/advisory/multiple-vulnerabilities-in-imonitorsoft-eam/ referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CISA ADP 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CNA 3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Affected products

  • iMonitor Software Inc. iMonitor EAM

Classification

Weakness
  • CWE-732 Incorrect Permission Assignment for Critical Resource

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.