Skip to content
Fencer Intel
medium 6.3

CVE-2025-1537 json

Harpia DiagSystem atualatendimento_jpeg.php sql injection

published last yr. modified 4mo ago also EUVD-2025-4519

cvss
6.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 32%
public exploits
0
none known

Summary

A vulnerability was found in Harpia DiagSystem 12. It has been rated as critical. This issue affects some unknown processing of the file /diagsystem/PACS/atualatendimento_jpeg.php. The manipulation of the argument codexame leads to sql injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Is CVE-2025-1537 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
Proof of concept is public
Automatable
no
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.38% chance of exploitation in the next 30 days, higher than 32% of all scored CVEs (FIRST EPSS, 2026-11-11).

Exploits and checks

  • drive.google.com https://drive.google.com/file/d/10IspKbYh7TYmxRPRIQZ7oRg6Xise8ykJ/view?usp=sharing referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N
CNA 3.1 6.3 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CNA 3.0 6.3 CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
CNA 2.0 6.5 AV:N/AC:L/Au:S/C:P/I:P/A:P
CNA 4.0 5.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Harpia DiagSystem

Classification

Weakness
  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command
  • CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.