CVE-2025-23405 json

Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Improper Output Neutralization For Logs

published last yr. modified 4mo ago also EUVD-2025-5940

cvss
5.3
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 21%
public exploits
0
none known

Summary

Unauthenticated log effects metrics gathering incident response efforts and potentially exposes risk of injection attacks (ex log injection).

Patch / fix

  • Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications 5.8.7.0.36

Is CVE-2025-23405 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSMA-25-058-01 updated cvss 5.3

Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application

  • Dario Health Dario Application Database and Internet-based Server Infrastructure Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications <=5.8.7.0.36
    affected: mitigation “Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.” dariohealth.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.29% chance of exploitation in the next 30 days, higher than 21% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 5.3 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
CNA 4.0 6.9 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications
  • Dario Health Dario Application Database and Internet-based Server Infrastructure

Classification

Weakness
  • CWE-117 Improper Output Neutralization for Logs