Skip to content
Fencer Intel
high 7.1

CVE-2025-24849 json

Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application Cleartext Transmission of Sensitive Information

published last yr. modified 4mo ago also EUVD-2025-5938

cvss
7.1
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.1%
EPSS 0.1% chance of exploitation in 30 days, percentile 0%
public exploits
0
none known

Summary

Lack of encryption in transit for cloud infrastructure facilitating potential for sensitive data manipulation or exposure.

Patch / fix

  • Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications 5.8.7.0.36

Is CVE-2025-24849 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSMA-25-058-01 updated cvss 7.1

Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Application

  • Dario Health Dario Application Database and Internet-based Server Infrastructure Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications <=5.8.7.0.36
    affected: mitigation “Dario Health recommends users update their Dario Health Android mobile application to the latest version. No other actions are required by users.” dariohealth.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
total
Assessed
last yr.

Exploit prediction

0.09% chance of exploitation in the next 30 days, higher than 0% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 7.1 CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H
CNA 4.0 7.5 CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 7.5 CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Dario Health USB-C Blood Glucose Monitoring System Starter Kit Android Applications
  • Dario Health Dario Application Database and Internet-based Server Infrastructure

Classification

Weakness
  • CWE-319 Cleartext Transmission of Sensitive Information

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.