Skip to content
Fencer Intel
high 7.5

CVE-2025-2875 json

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality wh…

published last yr. modified 4mo ago also EUVD-2025-14678

cvss
7.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.4%
EPSS 0.4% chance of exploitation in 30 days, percentile 38%
public exploits
0
none known

Summary

CWE-610: Externally Controlled Reference to a Resource in Another Sphere vulnerability exists that could cause a loss of confidentiality when an unauthenticated attacker manipulates controller’s webserver URL to access resources.

Is CVE-2025-2875 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-140-08 updated cvss 7.5

Schneider Electric Modicon Controllers (Update B)

  • Schneider Electric Modicon Controllers LMC058 <5.0.4.19
    affected: vendor fix, mitigation se.com
  • Schneider Electric Modicon Controllers M241 <5.3.12.48
    affected: vendor fix, mitigation se.com
  • Schneider Electric Modicon Controllers M251 <5.3.12.48
    affected: vendor fix, mitigation se.com
  • Schneider Electric Modicon Controllers M258 <5.0.4.19
    affected: vendor fix, mitigation se.com
  • Schneider Electric EcoStruxure Automation Expert - Motion 24.1 Modicon Controllers M241 5.3.12.48, Modicon Controllers M251 5.3.12.48 Schneider Electric EcoStruxure Machine Expert 2.3 Modicon Controllers M241 5.3.12.48, Modicon Controllers M251 5.3.12.48 Schneider Electric Modicon Controllers LMC058 Modicon Controllers LMC058 5.0.4.19 Schneider Electric Modicon Controllers M241 Modicon Controllers M241 5.3.12.48 Schneider Electric Modicon Controllers M251 Modicon Controllers M251 5.3.12.48 Schneider Electric Modicon Controllers M258 Modicon Controllers M258 5.0.4.19
    fixed

Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.44% chance of exploitation in the next 30 days, higher than 38% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CNA 4.0 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Schneider Electric Modicon Controllers M241 / M251
  • Schneider Electric Modicon Controllers M258 / LMC058

Classification

Weakness
  • CWE-610 Externally Controlled Reference to a Resource in Another Sphere

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.