Skip to content
Fencer Intel
critical 9.4

CVE-2025-29628 json

A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home…

published last yr. modified 4mo ago also EUVD-2025-22717

cvss
9.4
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 22%
public exploits
0
none known

Summary

A Gardyn Azure IoT Hub connection string is downloaded over an insecure HTTP connection in Gardyn Home Kit firmware before master.619, Home Kit Mobile Application before 2.11.0, and Home Kit Cloud API before 2.12.2026 leaving the string vulnerable to interception and modification through a Man-in-the-Middle attack. This may result in the attacker capturing device credentials or taking control of vulnerable home kits.

Patch / fix

  • Gardyn Home Kit Firmware master.619

Is CVE-2025-29628 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-26-055-03 updated cvss 8.3

Gardyn Home Kit (Update B)

  • Gardyn Home Firmware <master.622 Gardyn Studio Firmware <master.622
    affected: mitigation “The current versions of the Gardyn App and the Gardyn Home firmware can be checked in the Gardyn App.” mygardyn.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
Proof of concept is public
Automatable
yes
Technical impact
total
Assessed
last yr.

Exploit prediction

0.30% chance of exploitation in the next 30 days, higher than 22% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 9.4 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L
CISA ADP 3.1 8.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
CNA 3.1 8.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N

Affected products

  • Gardyn Home Kit Firmware

Classification

Weakness
  • CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel
  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor
  • CWE-77 Improper Neutralization of Special Elements used in a Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.