CVE-2025-34162 json
Bian Que Feijiu Intelligent Emergency and Quality Control System SQL Injection via GetLyfsByParams
published last yr. modified last mo. also EUVD-2025-26059
- cvss
- 9.3
- version 4.0, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.6%
- EPSS 0.6% chance of exploitation in 30 days, percentile 50%
- public exploits
- 0
- none known
Summary
An unauthenticated SQL injection vulnerability exists in the GetLyfsByParams endpoint of Bian Que Feijiu Intelligent Emergency and Quality Control System, accessible via the /AppService/BQMedical/WebServiceForFirstaidApp.asmx interface. The backend fails to properly sanitize user-supplied input in the strOpid parameter, allowing attackers to inject arbitrary SQL statements. This can lead to data exfiltration, authentication bypass, and potentially remote code execution, depending on backend configuration. The vulnerability is presumed to affect builds released prior to June 2025 and is remediated in newer versions of the product, though the exact affected range remains undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-23 UTC.
Patch / fix
- ivtbq.com/ patch
Is CVE-2025-34162 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- none
- Automatable
- yes
- Technical impact
- partial
- Assessed
- last yr.
Exploit prediction
0.64% chance of exploitation in the next 30 days, higher than 50% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- cn-sec.com https://cn-sec.com/archives/4160402.html referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H |
| CNA | 4.0 | 9.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Feijiu Medical Technology Co., Ltd. Bian Que Feijiu Intelligent Emergency and Quality Control System
Classification
- Weakness
-
- CWE-89 Improper Neutralization of Special Elements used in an SQL Command
References
-
ivtbq.com
/
product, patch
-
cn-sec.com
/archives/4160402.html
technical-description, exploit
-
github.com
/wooluo/nuclei-templates-2025hw/blob/main/bianque-medical-sql-injection.yaml
signature
-
vulncheck.com
/advisories/bian-que-feiju-intelligent-emergency-and-quality-control-system-sqli
third-party-advisory
Sources
- CVE List CVE-2025-34162
- NVD CVE-2025-34162
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.