Skip to content
Fencer Intel
high 8.8

CVE-2025-4008 kev in the critical feed json

Arbitrary Command Injection in Smartbedded MeteoBridge

published last yr. modified 4mo ago also EUVD-2025-16032

cvss
8.8
version 3.1, NVD
cisa kev
Exploited
added 2025-10-02
epss
93.3%
EPSS 93.3% chance of exploitation in 30 days, percentile 99.8%
public exploits
0
none known, plus a Nuclei check

Summary

The Meteobridge web interface let meteobridge administrator manage their weather station data collection and administer their meteobridge system through a web application written in CGI shell scripts and C.

This web interface exposes an endpoint that is vulnerable to command injection.

Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices.

Patch / fix

cisa required action Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.

  • smartbedded meteobridge_vm 6.2
  • smartbedded meteobridge_firmware 6.2

Is CVE-2025-4008 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Timeline

  1. Published
  2. Added to CISA KEV
  3. CISA SSVC: exploitation active
  4. CISA patch deadline

Known exploited

Added
last yr.
Patch by
2025-10-23 (last yr.)
Ransomware
Not known
Required action
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
Vendor, product
Smartbedded, Meteobridge
CISA name
Smartbedded Meteobridge Command Injection Vulnerability

CISA SSVC

Exploitation
Active, exploited in the wild
Automatable
yes
Technical impact
total
Assessed
last yr.

Exploit prediction

93.32% chance of exploitation in the next 30 days, higher than 99.8% of all scored CVEs (FIRST EPSS, 2026-11-09).

Exploits and checks

  • Nuclei template MeteoBridge <= 6.1 - Remote Code Execution nuclei detection template
  • onekey.com https://www.onekey.com/resource/security-advisory-remote-command-execution-on-smartbedded-meteobridge-cve-2025-4008 referenced PoC, tagged "exploit" by a source, unverified

CVSS scores

assigned by version score vector
CNA 4.0 8.7 CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CNA 4.0 8.7 CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
NVD 3.1 8.8 CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Affected products

  • Smartbedded MeteoBridge

Classification

Weakness
  • CWE-77 Improper Neutralization of Special Elements used in a Command
  • CWE-306 Missing Authentication for Critical Functionality

References

Sources