CVE-2025-40888 json
Authenticated SQL Injection on CLI functionality in Guardian/CMC before 25.3.0
published last yr. modified 22d ago also EUVD-2025-32082
- cvss
- 5.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.2%
- EPSS 0.2% chance of exploitation in 30 days, percentile 16%
- public exploits
- 0
- none known
Summary
A SQL Injection vulnerability was discovered in the CLI functionality due to improper validation of an input parameter. An authenticated user with limited privileges can execute arbitrary SELECT SQL statements on the DBMS used by the web application, potentially exposing unauthorized data.
Patch / fix
- Nozomi Networks Guardian 25.3.0
- Nozomi Networks CMC 25.3.0
Is CVE-2025-40888 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSA-25-226-09 updated cvss 5.3
Siemens RUGGEDCOM APE1808
-
Siemens RUGGEDCOM APE1808affected: vendor fix, mitigation
Facts from CISA's republication of the vendor's own advisory (CSAF); the linked advisory is the authoritative source. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- last yr.
Exploit prediction
0.25% chance of exploitation in the next 30 days, higher than 16% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 6.0 | CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 3.1 | 5.3 | CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N |
| CNA | 4.0 | 6.0 | CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 6.5 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N |
Affected products
- Nozomi Networks Guardian
- Nozomi Networks CMC
Classification
- Weakness
-
- CWE-89 Improper Neutralization of Special Elements used in an SQL Command
References
-
security.nozominetworks.com
/NN-2025:10-01
vendor-advisory
Sources
- CVE List CVE-2025-40888
- NVD CVE-2025-40888
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.