Skip to content
Fencer Intel
medium 6.5

CVE-2025-52459 json

Advantech iView Argument Injection

published last yr. modified 4mo ago also EUVD-2025-21077

cvss
6.5
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
0.3%
EPSS 0.3% chance of exploitation in 30 days, percentile 26%
public exploits
0
none known

Summary

A vulnerability exists in Advantech iView that allows for argument injection in NetworkServlet.backupDatabase(). This issue requires an authenticated attacker with at least user-level privileges. Certain parameters can be used directly in a command without proper sanitization, allowing arbitrary arguments to be injected. This can result in information disclosure, including sensitive database credentials.

Patch / fix

  • Advantech iView 5.7.05 build 7057

Is CVE-2025-52459 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

Vendor advisories

What the vendors themselves say about their products: affected, fixed or not affected, and what to do.

cisa ICSA-25-191-08 updated cvss 6.5

Advantech iView

  • Advantech iView <5.7.05_build_7057
    affected: mitigation “Advantech recommends users update to v5.7.05 build 7057.” advantech.com

From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf

CISA SSVC

Exploitation
none
Automatable
no
Technical impact
partial
Assessed
last yr.

Exploit prediction

0.33% chance of exploitation in the next 30 days, higher than 26% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 6.5 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
CNA 4.0 7.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CNA 4.0 7.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Affected products

  • Advantech iView

Classification

Weakness
  • CWE-88 Improper Neutralization of Argument Delimiters in a Command

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.