CVE-2025-52562 json

Convey Panel Directory Traversal in LocaleController leading to Remote Code Execution

published last yr. modified 4mo ago also EUVD-2025-18951

cvss
10.0
version 3.1, CNA
cisa kev
Not listed
not in CISA's catalog
epss
1.8%
EPSS 1.8% chance of exploitation in 30 days, percentile 78%
public exploits
0
none known

Summary

Convoy is a KVM server management panel for hosting businesses. In versions 3.9.0-rc3 to before 4.4.1, there is a directory traversal vulnerability in the LocaleController component of Performave Convoy. An unauthenticated remote attacker can exploit this vulnerability by sending a specially crafted HTTP request with malicious locale and namespace parameters. This allows the attacker to include and execute arbitrary PHP files on the server. This issue has been patched in version 4.4.1. A temporary workaround involves implementing strict Web Application Firewall (WAF) rules to incoming requests targeting the vulnerable endpoints.

Patch / fix

  • convoypanel convoy 4.4.1

Is CVE-2025-52562 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.

Check with Fencer

CISA SSVC

Exploitation
none
Automatable
yes
Technical impact
total
Assessed
last yr.

Exploit prediction

1.82% chance of exploitation in the next 30 days, higher than 78% of all scored CVEs (FIRST EPSS, 2026-11-09).

CVSS scores

assigned by version score vector
CNA 3.1 10.0 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Affected products

  • ConvoyPanel panel

Classification

Weakness
  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory
  • CWE-98 Improper Control of Filename for Include/Require Statement in PHP Program

References

Sources

Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.

CPEs and fixed versions use Anchore's correction of NVD's data: Added CPE configurations because not yet analyzed by NVD.