CVE-2025-54459 json
Vertikal Systems Hospital Manager Backend Services Exposure of Sensitive System Information to an Unauthorized Control Sphere
published last yr. modified last mo. also EUVD-2025-36741
- cvss
- 7.5
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 0.4%
- EPSS 0.4% chance of exploitation in 30 days, percentile 36%
- public exploits
- 0
- none known
Summary
Prior to September 19, 2025, the Hospital Manager Backend Services exposed the ASP.NET tracing endpoint /trace.axd without authentication, allowing a remote attacker to obtain live request traces and sensitive information such as request metadata, session identifiers, authorization headers, server variables, and internal file paths.
Is CVE-2025-54459 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerVendor advisories
What the vendors themselves say about their products: affected, fixed or not affected, and what to do.
cisa ICSMA-25-301-01 updated cvss 7.5
Vertikal Systems Hospital Manager Backend Services
-
Vertikal Systems Hospital Manager Backend Services <=September_19_2025affected: mitigation “Vertikal Systems fixed these vulnerabilities by September 19, 2025. For more information, users should contact Vertikal Systems support for assistance.” vertikalsystems.com
From CISA ICS and IT advisories (CSAF, https://github.com/cisagov/CSAF), a U.S. Government work; changed: reduced to products, statuses and remediations. CISA notification · csaf
CISA SSVC
- Exploitation
- none
- Automatable
- no
- Technical impact
- partial
- Assessed
- last yr.
Exploit prediction
0.42% chance of exploitation in the next 30 days, higher than 36% of all scored CVEs (FIRST EPSS, 2026-11-09).
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N |
| CNA | 3.1 | 7.5 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N |
| CNA | 4.0 | 8.7 | CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
Affected products
- Vertikal Systems Hospital Manager Backend Services
Classification
- Weakness
-
- CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere
References
-
cisa.gov
/news-events/ics-medical-advisories/icsma-25-301-01
mitigation, third-party-advisory, us-government-resource
Sources
- CVE List CVE-2025-54459
- NVD CVE-2025-54459
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.