CVE-2025-5446 json
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 RP_checkCredentialsByBBS os command injection
published last yr. modified 4mo ago also EUVD-2025-16660
- cvss
- 6.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 13.7%
- EPSS 13.7% chance of exploitation in 30 days, percentile 96%
- public exploits
- 0
- none known
Summary
A vulnerability was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. It has been classified as critical. This affects the function RP_checkCredentialsByBBS of the file /goform/RP_checkCredentialsByBBS. The manipulation of the argument pwd leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Is CVE-2025-5446 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- no
- Technical impact
- partial
- Assessed
- last yr.
Exploit prediction
13.69% chance of exploitation in the next 30 days, higher than 96% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- github.com https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_9/9.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N |
| CNA | 3.1 | 6.3 | CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.0 | 6.3 | CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L |
| CNA | 2.0 | 6.5 | AV:N/AC:L/Au:S/C:P/I:P/A:P |
| CNA | 4.0 | 5.3 | CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X |
| NVD | 3.1 | 9.8 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H |
Affected products
- Linksys RE6500
- Linksys RE6250
- Linksys RE6300
- Linksys RE6350
- Linksys RE7000
- Linksys RE9000
Classification
References
-
github.com
/wudipjq/my_vuln/blob/main/Linksys/vuln_9/9.md
exploit, third-party-advisory
-
vuldb.com
/?id.310785
vdb-entry, technical-description, third-party-advisory
-
vuldb.com
/?ctiid.310785
signature, permissions-required, vdb-entry
-
vuldb.com
/?submit.584368
third-party-advisory, vdb-entry
-
linksys.com
/
product
Sources
- CVE List CVE-2025-5446
- NVD CVE-2025-5446
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.