CVE-2025-60697 json
A command injection vulnerability exists in the D-Link DIR-882 Router firmware DIR882A1_FW102B02 within the `prog.cgi` and `rc` binaries.
published 11mo ago modified 4d ago also EUVD-2025-175344
- cvss
- 7.3
- version 3.1, CNA
- cisa kev
- Not listed
- not in CISA's catalog
- epss
- 3.8%
- EPSS 3.8% chance of exploitation in 30 days, percentile 90%
- public exploits
- 0
- none known
Summary
A command injection vulnerability exists in the D-Link DIR-882 Router firmware DIR882A1_FW102B02 within the `prog.cgi` and `rc` binaries. The `sub_4438A4` function in `prog.cgi` stores user-supplied DDNS parameters (`ServerAddress` and `Hostname`) in NVRAM via `nvram_safe_set`. These values are later retrieved in the `start_DDNS_ipv4` function of `rc` using `nvram_safe_get` and concatenated into DDNS shell commands executed via `twsystem()` without proper sanitization. Partial string comparison is performed but is insufficient to prevent command injection. An unauthenticated remote attacker can exploit this vulnerability to execute arbitrary commands on the device through specially crafted HTTP requests to the router's web interface.
Is CVE-2025-60697 in your stack? Fencer shows which of your repositories are affected as soon as an advisory lands, and opens the fix as a pull request.
Check with FencerCISA SSVC
- Exploitation
- Proof of concept is public
- Automatable
- yes
- Technical impact
- partial
- Assessed
- 11mo ago
Exploit prediction
3.82% chance of exploitation in the next 30 days, higher than 90% of all scored CVEs (FIRST EPSS, 2026-11-09).
Exploits and checks
- github.com https://github.com/yifan20020708/SGTaint-0-day/blob/main/DLink/DLink-DIR-882/CVE-2025-60697.md referenced PoC, tagged "exploit" by a source, unverified
CVSS scores
| assigned by | version | score | vector |
|---|---|---|---|
| CISA ADP | 3.1 | 7.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L |
| CNA | 3.1 | 7.3 | CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L |
Classification
- Weakness
-
- CWE-77 Improper Neutralization of Special Elements used in a Command
References
-
github.com
/yifan20020708/SGTaint-0-day/blob/main/DLink/DLink-DIR-882/CVE-2025-60697.md
exploit, third-party-advisory
-
dlink.com
/en/security-bulletin/
vendor-advisory
-
dlink.com
/
product
-
github.com
/yifan20020708/SGTaint-0-day/blob/main/DLink/DLink-DIR-882/4.md
broken-link
Sources
- CVE List CVE-2025-60697
- NVD CVE-2025-60697
Fencer Intel keeps one entry per vulnerability: the CVE id wins, then GHSA, and records that alias each other are merged, except that two CVEs always keep separate entries. The same data is available as JSON.